激情五月综合人妻婷婷_日本少妇自慰免费完整版_国产在线青青草原_狠狼鲁亚洲综合网http_欧美老熟妇xB水多毛多rv_国产3p黑人20分钟观看_菠萝菠萝蜜免费高清在线观看1_在线欧美一区二区_一本久久中文无码_久揄揄鲁一二三四区

歡迎光臨揚州市培英實驗儀器有限公司官網(wǎng)!
培養(yǎng)箱設(shè)備源頭制造集研發(fā)、設(shè)計、生產(chǎn)、銷售為一體
全國咨詢熱線:18021721029

電加熱恒溫箱有什么機械故障呢

時間:2021-07-16 08:52:31 來源:[db:來源] 點擊:333次

電加熱恒溫箱有什么機械故障呢?出現(xiàn)了常見故障又應(yīng)當(dāng)如何開展檢修呢?對于這2個難題人們接下去逐一認識一下。

What is the mechanical failure of the electric heating thermostat? How to carry out the overhaul when there are common faults? For these two problems, people will go on to understand one by one.

1、電加熱恒溫箱工作中室溫不勻稱,出現(xiàn)這種情況,應(yīng)查驗恒溫箱箱里物件是不是阻塞送風(fēng)模式道通風(fēng)口或是是進氣口,還是恒溫箱箱里物件過多。

1. The room temperature of the electric heating thermostat is not symmetrical. In this case, it should be checked whether the objects in the thermostat block the ventilation outlet of the air supply mode or the air inlet, or whether there are too many objects in the thermostat.

2、培養(yǎng)箱不加熱同時伴有報警聲,但培養(yǎng)箱循環(huán)風(fēng)機正常工作,同時溫控示“———",此故障為培養(yǎng)箱傳感器損壞,更換一下傳感器就可以了。

2. The incubator is not heated and accompanied by alarm sound, but the incubator circulating fan works normally, and the temperature control "-". This fault is the incubator sensor damage, just replace the sensor.

3、電熱培養(yǎng)箱打開電源開關(guān)出現(xiàn)跳閘現(xiàn)象,出現(xiàn)此類情況可直接考慮更換培養(yǎng)箱加熱管,另保險絲座損壞也會出現(xiàn)此現(xiàn)象,但極少見。

3. The switch of power supply in the electrothermal incubator trips, which can be directly considered to replace the incubator heating tube. In addition, the fuse holder damage will also occur, but it is rare.

4、恒溫箱接入開關(guān)電源后,開啟恒溫箱電源總開關(guān)無顯示信息,多見保險管融斷,拆換就能,若保險管完好無損,立即拆換電源總開關(guān)。

4. When the thermostat is connected to the switching power supply, the main switch of the power supply of the thermostat has no display information. Most of the fuses are broken, and the fuses can be removed. If the fuses are intact, the main switch of the power supply should be removed immediately.

5、電熱培養(yǎng)箱不加熱但溫控儀顯示正常,培養(yǎng)箱此故障多為加熱損壞,更換即可,在檢修培養(yǎng)箱該故障時應(yīng)確保循環(huán)風(fēng)機正常運行。如果培養(yǎng)箱循環(huán)風(fēng)機不運轉(zhuǎn)也會引起不加熱現(xiàn)象,但培養(yǎng)箱箱內(nèi)溫度會有5℃左右的溫升,打開箱門時會有少量焦糊味道,比較容易判斷是培養(yǎng)箱加熱管或者是循環(huán)風(fēng)機故障。

5. The incubator is not heated, but the temperature controller shows normal. The incubator is usually damaged by heating. It can be replaced. When overhauling the incubator, the circulating fan should be ensured to run normally. If the circulating fan of the incubator does not work, it will also cause no heating phenomenon, but the temperature in the incubator will rise about 5 C. When the door of the incubator is opened, there will be a small amount of burnt taste. It is easier to judge whether the incubator heating pipe or the circulating fan is out of order.http://www.crxyq.cn/


 

聯(lián)系方式
聯(lián)系方式

熱線電話

18021721029

上班時間

周一到周五

公司電話

18021721029

二維碼
聯(lián)
Tokenim钱包app|tokenim官方下载 - 你的通用数字钱包